japan CM Series Spectrophotometers
Time:2018-04-14 Click:1595
We can also supply all the color measuring spectrophotometer from japan, such as CM-2300d, CM-2500c, CM-2500d, CM-2600d, CM-600d, CM-700d, together wiht the benchtop spectrophotometer CM-3600A, CM-5 and other models.
And also the CR series color reader, such as CR-10PLUS, CR-400/410.
Specifications
Model | CM-700d |
---|---|
Model Name | CM-700d Spectrophotometer |
Illumination/ viewing system | di: 8°, de: 8° (diffused illumination, 8° viewing angle), SCI (specular component included)/SCE (specular component excluded) selectable with automatic switching (Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil7, ASTM E 1164, and JIS Z 8722) |
Size of integrating sphere | Φ40mm |
Detector | Silicon photodiode array (dual 36-element) |
Spectral separation device | Diffraction grating |
Wavelength range | 400 nm to 700 nm |
Wavelength pitch | 10 nm |
Half bandwitdh | Approx. 10 nm |
Reflectance range | 0 to 175%, Display resolution: 0.01% |
Light source | Pulsed xenon lamp (with UV cut filter) |
Measurement time | Approx. 1 second |
Minimum measurement interval | Approx. 2 second (in SCI or SCE mode) |
Battery performance |
With alkaline dry batteries: Approx. 2,000 measurements With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2,000 measurements with full charge * Stand-alone continuous measurement fi xed to either SCI or SCE mode at 10-second intervals at 23°C |
Measurement/ illumination area | MAV: Φ8 mm/ Φ11 mm only |
Repeatability |
Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation withinΔE*ab 0.04 * When a white calibration plate is measured 30 x at 10-second intervals after white calibration |
Inter-instrument agreement |
WithinΔE*ab 0.2 (MAV/SCI) * Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C |
No. of averaging measurements | 1 to 10 (Auto averaging), 1 to 30 (Manual averaging) |
Display | 2.36-inch TFT color LCD |
Interfaces | USB1.1; Bluetooth reg; standard version 1.2* |
Observer | 2° observer or 10 deg; observer |
Illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (Simultaneous evaluation with two light sources possible) |
Displayed data | Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, pseudocolor, color assessment |
Color spaces | L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell) |
Colorimetric data | MI, WI(ASTM E313-73/E313-96), YI(ASTM E313-73/ASTM D1925), ISO Brightness, 8°gloss value |
Color difference formulas | ΔE*ab (CIE1976),ΔE*94 (CIE1994),ΔE00 (CIE 2000), CMC (l: c) |
Color difference formulas | ΔE*ab (CIE1976), ΔE*94 (CIE1994), ΔE00 (CIE2000), CMC (l: c), Hunter ΔE |
Storable Data Sets | Measurement data: 3,000 sets/ Target color difference data: 1,000 sets |
Pass/Fail Judgment | Tolerances can be set to colorimetric values (exclusing Munsell), color diffference values, color values (excluding 8° gloss value) respectively |
Power | Special AC adapter; 4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries. |
Size | 73 (W) x 211.5 (H) x 107 (D) mm |
Weght | Approx. 550 g (without white calibration cap and batteries) |
Operating temperature/ humidity range | 5 to 40 ° C, relative humidity 80% or less (at 35° C) with no condensation |
Storage temperature/ humidity range | 0 to 45 ° C, relative humidity 80% or less (at 35° C) with no condensation |
Specifications
Model | CM-2600d |
---|---|
Model | CM-2600d |
Illumination / observation system | d/8° (diffuse illumination, 8-degree viewing ), equipped with simultaneous measurement of SCI (specular component included)/SCE (specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard. |
Size of Integrating Sphere | Φ 52mm |
Detector | Silicon photodiode array (dual 40 elements) |
Spectral separation device | Diffraction grating |
Wavelength range | 360nm to 740nm |
Wavelength pitch | 10nm |
Half bandwidth | Approx. 10nm |
Reflectance range | 0 to 175%, resolution: 0.01% |
Light source | 3 pulsed xenon lamps (2 xon lamps forCM-2500 d) |
Measurement time | Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement) |
Minimum interval between measurements |
3 seconds for SCI/SCE (4 seconds for fluorescent measurement) (simultaneous evaluation of SCI/SCE is possible by a single measurement) |
Measurement/Illumination area |
MAV: Φ8mm / Φ 11 mm SAV: Φ 3mm/ Φ 6mm (Selectable between MAV and SAV) (Only MAV is available for CM-2500d) |
Repeatability |
(Standard deviation) Spectral Reflectance: within 0.1% (360 to 380nm within 0.2%) Chromaticity Value : ΔE*ab 0.04(When a white calibration plate is measured 30 times at 10-second intervals after white calibration) |
Inter instrument agreement | ΔE*ab within 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body. |
UV adjustment | Instantaneous numerical adjustment (no mechanical adjustment required) With UV400nm cut filter |
Measurement mode | Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 times/manual mode) |
Interface | Output: RS-232C serial signals via RJ45 connector; USB 2.0 communication possible when using included USB-Serial Converter Cable IF-A24 |
Observer | 2/10° (CIE 1931/2°,CIE 1964/10°) |
Illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) |
Outputs | Spectral value/graph, colorimetric value, color difference value/graph, PASS / FAIL result, relativity gloss value |
Data Memory |
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the defined in COND mode. *Total of the sample data for the COND and TASK modes and color difference target data |
Battery performance | Alkaline manganese:approx. 1000 measurements |
Display data | Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result |
Color space / colorimetric data | L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00 |
Tolerance display | Tolerance for color difference (both box and eliptical tolerances can be set) |
Power source | 4 AA-size battery or AC adapter |
Size (WxHxD) | 69 x 96 x 193mm |
Weight | Approx. 670g (without batteries) |
Operating temperature / humidity range (*1) | 5 to 40°C, relative humidity 80% or less (at 35°C) with no condensation |
Storage temperature/humidity range | 0 to 45°C, relative humidity 80% or (at 35°C) with no condensation |
Standard accessories | White calibration plate, Target mask Φ8mm, Target mask Φ3mm , RS-232C cable, AC adapter,AA-size battery (x4) |
Optional Accessories | Hard case, Dust cover set, Dust cover, SpectraMagicTM NX (software), Zero calibration box |
Specifications
Model | CM-2500D |
---|---|
Model | CM-2500d |
Illumination / observation system | d/8 (diffuse illumination, 8° viewing ), equipped with simultaneous measurement of SCI (specular component included)/SCE (specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard. |
Sphere Size | Φ52mm |
Light-receiving element | Silicon photodiode array (dual 40 elements) |
Spectral separation device | Diffraction grating |
Wavelength range | 360nm to 740nm |
Wavelength pitch | 10nm |
Half bandwitdh | Approx. 10nm |
Reflectance range | 0 to 175%, resolution: 0.01% |
Light source | 2 pulsed xenon lamps |
Measurement time | Approx. 1.5 seconds |
Minimum interval between measurements | 3 seconds for SCI/SCE |
Battery performance | Alkaline manganese:approx. 1000 measurements |
Measurement/illumination area | MAV : Φ8mm/ Φ11mm |
Repeatability |
Spectral Reflectance: Standard deviation within 0.1% (360 to 380nm within 0.2%) Colorimetric Value : Standard deviation within ΔE*ab 0.04(Measurement conditions:White calibration plate measured 30 x at 10-second intervals after white calibration was performed) |
Inter instrument agreement | within ΔE*ab 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body. |
UV adjustment | No UV adjustment |
Measurement mode | Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 x/manual mode) |
Interface | RS-232C serial signals via RJ45 connector; USB 2.0 communication possible when using included USB-Serial Converter Cable IF-A24 |
Observer | 2/10 degrees (CIE 1931/2°,CIE 1964/10°) |
Illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources) |
Display data | Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result |
Color space / colorimetric data | L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00 |
Data memory |
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the "defined in COND." mode. * Total of the sample data for the COND and TASK modes and color diference target data |
Tolerance judgment | Tolerance for color difference (both box and eliptical tolerances can be set) |
Power source | 4 AA-size battery or AC adapter |
Size (W x;H x;D) | 69 x; 96 x; 193mm |
Weight | Approx. 670g (without batteries) |
Operating temperature / humidity range (*1) | 5 to 40°C, relative humidity 80% or less (at 35°C) with no condensation |
Storage temperature/humidity range | 0 to 45°C, relative humidity 80% or (at 35°C) with no condensation |
Standard accessories | White calibration plate, Target mask Φ8mm, Target mask Φ3mm , RS-232C cable, AC adapter,AA-size battery ( x;4) |
Optional Accessories | Hard case, Dust cover set, Dust cover, SpectraMagic trade;NX (software), Zero calibration box |
Specifications
Model | CM-3600A |
---|---|
Illumination/observation system |
Reflectance; di:8°, de:8°; (diffused illumination, 8° viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded); Conforms to CIE No.15, lSO7724/1, ASTM E-1164, DIN 5033 Teil7 and JIS Z8722 condition C standard. Transmittance : di:0°, de:0° (diffused illumination, 0° viewing); Conforms to CIE No.15, ASTM E-1164 and DIN 5033 Teil7 standard. |
Light-receiving element | Silicon photodiode array (dual 40 elements) |
Spectral separation device | Diffraction grating |
Wavelength range | 360 to 740 nm |
Wavelength pitch | 10 nm |
Half bandwitdh | Approx. 10 nm |
Reflectance range | 0 to 200%; Resolution: 0.01% |
Sphere size | Φ 152 mm |
Light source | Four pulsed xenon lamps |
Minimum interval between measurements | Normal SCI/ SCE measurement: 4 sec. UV-cut / UV-adjusted measurement: 5 sec. Transmittance measurement: 3 sec. |
Measurement/illumination areas |
Reflectance: Changeable between LAV, MAV, and SAV LAV: Φ 25.4 mm / Φ 30 mm MAV: Φ 8 mm / Φ 11 mm SAV: Φ 4 mm / Φ 7 mm Transmittance: Approx. O 24 mm |
Repeatability |
When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within ΔE*ab 0.02 |
Inter instrument agreement | Mean ΔE*ab 0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body |
UV adjustment | Instantaneous numerical adjustment |
UV cut filters | 400 nm cutoff and 420 nm cutoff |
Transmittance chamber |
Witdh: 133 mm, Depth: Approx. 50 mm; Measurement diameter: Approx. 17 mm Transmission sample holder (optional accessory): Sample holder for both plate-shaped and liquid samples (removable); Liquid samples not measurable with CM-3610A. |
Interface | USB 1.1 |
Power | AC 100 to 240V 50/60Hz (using included AC adapter) |
Operating temperature/humidity range | 13 to 33°C) with no condensation |
Storage temperature/humidity range | 0 to 40°C) with no condensation |
Size (W x H x D) |
CM-3600A: 244 x 205 x 378 mm CM-3610A: 300 x 597 x 315 mm |
Weight |
CM-3600A: 11.5 kg CM-3610A: 16.5 kg |
PRE : NONE