japan CM Series Spectrophotometers

Time:2018-04-14 Click:1595



We can also supply all the color measuring spectrophotometer from japan, such as CM-2300d, CM-2500c, CM-2500d, CM-2600d, CM-600d, CM-700d, together wiht the benchtop spectrophotometer CM-3600A, CM-5 and other models.
And also the CR series color reader, such as CR-10PLUS, CR-400/410.

Specifications

Model CM-700d
Model Name CM-700d Spectrophotometer
Illumination/ viewing system di: 8°, de: 8° (diffused illumination, 8° viewing angle), SCI (specular component included)/SCE (specular component excluded) selectable with automatic switching (Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil7, ASTM E 1164, and JIS Z 8722)
Size of integrating sphere Φ40mm
Detector Silicon photodiode array (dual 36-element)
Spectral separation device Diffraction grating
Wavelength range 400 nm to 700 nm
Wavelength pitch 10 nm
Half bandwitdh Approx. 10 nm
Reflectance range 0 to 175%, Display resolution: 0.01%
Light source Pulsed xenon lamp (with UV cut filter)
Measurement time Approx. 1 second
Minimum measurement interval Approx. 2 second (in SCI or SCE mode)
Battery performance With alkaline dry batteries: Approx. 2,000 measurements With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2,000 measurements with full charge
* Stand-alone continuous measurement fi xed to either SCI or SCE mode at 10-second intervals at 23°C
Measurement/ illumination area MAV: Φ8 mm/ Φ11 mm only
Repeatability Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation withinΔE*ab 0.04
* When a white calibration plate is measured 30 x at 10-second intervals after white calibration
Inter-instrument agreement WithinΔE*ab 0.2 (MAV/SCI)
* Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C
No. of averaging measurements 1 to 10 (Auto averaging), 1 to 30 (Manual averaging)
Display 2.36-inch TFT color LCD
Interfaces USB1.1; Bluetooth reg; standard version 1.2*
Observer 2° observer or 10 deg; observer
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (Simultaneous evaluation with two light sources possible)
Displayed data Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, pseudocolor, color assessment
Color spaces L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell)
Colorimetric data MI, WI(ASTM E313-73/E313-96), YI(ASTM E313-73/ASTM D1925), ISO Brightness, 8°gloss value
Color difference formulas ΔE*ab (CIE1976),ΔE*94 (CIE1994),ΔE00 (CIE 2000), CMC (l: c)
Color difference formulas ΔE*ab (CIE1976), ΔE*94 (CIE1994), ΔE00 (CIE2000), CMC (l: c), Hunter ΔE
Storable Data Sets Measurement data: 3,000 sets/ Target color difference data: 1,000 sets
Pass/Fail Judgment Tolerances can be set to colorimetric values (exclusing Munsell), color diffference values, color values (excluding 8° gloss value) respectively
Power Special AC adapter; 4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries.
Size 73 (W) x 211.5 (H) x 107 (D) mm
Weght Approx. 550 g (without white calibration cap and batteries)
Operating temperature/ humidity range 5 to 40 ° C, relative humidity 80% or less (at 35° C) with no condensation
Storage temperature/ humidity range 0 to 45 ° C, relative humidity 80% or less (at 35° C) with no condensation

Specifications
Model CM-2600d
Model CM-2600d
Illumination / observation system d/8° (diffuse illumination, 8-degree viewing ), equipped with simultaneous measurement of SCI (specular component included)/SCE (specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard.
Size of Integrating Sphere Φ 52mm
Detector Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360nm to 740nm
Wavelength pitch 10nm
Half bandwidth Approx. 10nm
Reflectance range 0 to 175%, resolution: 0.01%
Light source 3 pulsed xenon lamps (2 xon lamps forCM-2500 d)
Measurement time Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement)
Minimum interval between measurements 3 seconds for SCI/SCE (4 seconds for fluorescent measurement)
(simultaneous evaluation of SCI/SCE is possible by a single measurement)
Measurement/Illumination area MAV: Φ8mm / Φ 11 mm
SAV: Φ 3mm/ Φ 6mm (Selectable between MAV and SAV)
(Only MAV is available for CM-2500d)
Repeatability (Standard deviation) Spectral Reflectance: within 0.1% (360 to 380nm within 0.2%)
Chromaticity Value : ΔE*ab 0.04(When a white calibration plate is measured 30 times at 10-second intervals after white calibration)
Inter instrument agreement ΔE*ab within 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body.
UV adjustment Instantaneous numerical adjustment (no mechanical adjustment required) With UV400nm cut filter
Measurement mode Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 times/manual mode)
Interface Output: RS-232C serial signals via RJ45 connector; USB 2.0 communication possible when using included USB-Serial Converter Cable IF-A24
Observer 2/10° (CIE 1931/2°,CIE 1964/10°)
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources)
Outputs Spectral value/graph, colorimetric value, color difference value/graph, PASS / FAIL result, relativity gloss value
Data Memory 1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the defined in COND mode.
*Total of the sample data for the COND and TASK modes and color difference target data
Battery performance Alkaline manganese:approx. 1000 measurements
Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result
Color space / colorimetric data L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00
Tolerance display Tolerance for color difference (both box and eliptical tolerances can be set)
Power source 4 AA-size battery or AC adapter
Size (WxHxD) 69 x 96 x 193mm
Weight Approx. 670g (without batteries)
Operating temperature / humidity range (*1) 5 to 40°C, relative humidity 80% or less (at 35°C) with no condensation
Storage temperature/humidity range 0 to 45°C, relative humidity 80% or (at 35°C) with no condensation
Standard accessories White calibration plate, Target mask Φ8mm, Target mask Φ3mm , RS-232C cable, AC adapter,AA-size battery (x4)
Optional Accessories Hard case, Dust cover set, Dust cover, SpectraMagicTM NX (software), Zero calibration box

Specifications

Model CM-2500D
Model CM-2500d
Illumination / observation system d/8 (diffuse illumination, 8° viewing ), equipped with simultaneous measurement of SCI (specular component included)/SCE (specular component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7 and JIS Z8722 Condition C standard.
Sphere Size Φ52mm
Light-receiving element Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360nm to 740nm
Wavelength pitch 10nm
Half bandwitdh Approx. 10nm
Reflectance range 0 to 175%, resolution: 0.01%
Light source 2 pulsed xenon lamps
Measurement time Approx. 1.5 seconds
Minimum interval between measurements 3 seconds for SCI/SCE
Battery performance Alkaline manganese:approx. 1000 measurements
Measurement/illumination area MAV : Φ8mm/ Φ11mm
Repeatability Spectral Reflectance: Standard deviation within 0.1% (360 to 380nm within 0.2%)
Colorimetric Value : Standard deviation within ΔE*ab 0.04(Measurement conditions:White calibration plate measured 30 x at 10-second intervals after white calibration was performed)
Inter instrument agreement within ΔE*ab 0.2 (MAV/SCI) Average for 12BCRA Series II color tiles compared to values measured with master body.
UV adjustment No UV adjustment
Measurement mode Single measurement/automatic averaging of multiple measurements(auto mode: 3, 5, 8 x/manual mode)
Interface RS-232C serial signals via RJ45 connector; USB 2.0 communication possible when using included USB-Serial Converter Cable IF-A24
Observer 2/10 degrees (CIE 1931/2°,CIE 1964/10°)
Illuminant A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources)
Display data Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result
Color space / colorimetric data L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470), Density statusA /T, WI/Tint (CIE/Ganz), CIE00
Data memory 1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the "defined in COND." mode.
* Total of the sample data for the COND and TASK modes and color diference target data
Tolerance judgment Tolerance for color difference (both box and eliptical tolerances can be set)
Power source 4 AA-size battery or AC adapter
Size (W x;H x;D) 69 x; 96 x; 193mm
Weight Approx. 670g (without batteries)
Operating temperature / humidity range (*1) 5 to 40°C, relative humidity 80% or less (at 35°C) with no condensation
Storage temperature/humidity range 0 to 45°C, relative humidity 80% or (at 35°C) with no condensation
Standard accessories White calibration plate, Target mask Φ8mm, Target mask Φ3mm , RS-232C cable, AC adapter,AA-size battery ( x;4)
Optional Accessories Hard case, Dust cover set, Dust cover, SpectraMagic trade;NX (software), Zero calibration box

Specifications

Model CM-3600A
Illumination/observation system Reflectance; di:8°, de:8°; (diffused illumination, 8° viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded); Conforms to CIE No.15, lSO7724/1, ASTM E-1164, DIN 5033 Teil7 and JIS Z8722 condition C standard.
Transmittance : di:0°, de:0° (diffused illumination, 0° viewing); Conforms to CIE No.15, ASTM E-1164 and DIN 5033 Teil7 standard.
Light-receiving element Silicon photodiode array (dual 40 elements)
Spectral separation device Diffraction grating
Wavelength range 360 to 740 nm
Wavelength pitch 10 nm
Half bandwitdh Approx. 10 nm
Reflectance range 0 to 200%; Resolution: 0.01%
Sphere size Φ 152 mm
Light source Four pulsed xenon lamps
Minimum interval between measurements Normal SCI/ SCE measurement: 4 sec. UV-cut / UV-adjusted measurement: 5 sec. Transmittance measurement: 3 sec.
Measurement/illumination areas Reflectance: Changeable between LAV, MAV, and SAV
LAV: Φ 25.4 mm / Φ 30 mm
MAV: Φ 8 mm / Φ 11 mm
SAV: Φ 4 mm / Φ 7 mm
Transmittance: Approx. O 24 mm
Repeatability When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: 
Spectral reflectance: Standard deviation within 0.1%
Colorimetric values: Standard deviation within ΔE*ab 0.02
Inter instrument agreement Mean ΔE*ab 0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body
UV adjustment Instantaneous numerical adjustment
UV cut filters 400 nm cutoff and 420 nm cutoff
Transmittance chamber Witdh: 133 mm, Depth: Approx. 50 mm; Measurement diameter: Approx. 17 mm
Transmission sample holder (optional accessory): Sample holder for both plate-shaped and liquid samples (removable); Liquid samples not measurable with CM-3610A.
Interface USB 1.1
Power AC 100 to 240V 50/60Hz (using included AC adapter)
Operating temperature/humidity range 13 to 33°C) with no condensation
Storage temperature/humidity range 0 to 40°C) with no condensation
Size (W x H x D) CM-3600A: 244 x 205 x 378 mm
CM-3610A: 300 x 597 x 315 mm
Weight CM-3600A: 11.5 kg
CM-3610A: 16.5 kg